250A Series – Three-Phase Voltage/Phase Monitor 系列 - Littelfuse 250A Voltage Monitoring Relays Provide Superior Protection

External overview image
滚动放大
免责声明

Littelfuse产品并非为以下用途而设计,也不应被用于这些用途:包括但不限于汽车、航空航天、医疗、救生、维生、核设施、高可靠性应用、用于手术植入体内的装置,或者在产品故障或运行无法达到理想状态的情况下会造成人身伤害、死亡或财产损失的任何其他应用。除非在适用的Littelfuse产品文档中已有明确说明。 如果将产品用于相关Littelfuse文件中未明确说明的任何其他用途,则产品不享受Littelfuse质保。 如果将产品用于相关Littelfuse文件中未明确说明的其他用途,则Littelfuse不会为因此造成的任何索赔或损失承担责任。 除非经Littelfuse另行许可,否则Littelfuse产品的销售和使用应遵守Littelfuse销售条款与条件。 "Littelfuse"包括Littelfuse, Inc.及其所有附属实体。

The 250A series is a three-phase, auto-ranging, dual-range voltage monitor that protects 190-480 V ac, 50*/60 Hz motors regardless of their size. This monitor offers protection from low- and high-voltage, voltage unbalance, single-phase, and phase reversal. The 250A provides a user-selectable nominal voltage setpoint and will automatically select between the 200 V and 400 V range. This monitor also features adjustable or manual restart delay.

This unique microcontroller-based voltage and phase-sensing device constantly monitors the three-phase voltages to detect harmful power line conditions. When a harmful condition is detected, the output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to acceptable levels. The 250A monitor includes advanced, single LED diagnostics. Five different light patterns distinguish between faults and normal conditions. LED indications include normal operation, power-up restart delay, reverse-phase trip, unbalance/single-phase trip, and high/low voltage trip.

*注: 50 Hz will increase all delay timers by 20 %.

功能与特色

  • Proprietary microcontroller-based circuitry
  • Auto-sensing wide voltage range
  • Advanced LED diagnostics
  • Adjustable trip delay
  • DPDT继电器输出
  • Manual reset

请在下方查看规格、认证和存货情况并订购零部件

Catalog #Input
Voltage (V)
Output
Form
Termination TypeMounting MethodDimensionsWeight (lbs/g)HumidityInput AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Overvoltage Reset Voltage (%)Overvoltage Trip Voltage (%)Restart Delay RangeStorage Temperature (F/C)Trip Delay RangeStockSamplesCompare
产品号输入
电压(V)
输出
型式
端接类型安装方法尺寸规格重量(磅/克)湿度Input AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Overvoltage Reset Voltage (%)Overvoltage Trip Voltage (%)Restart Delay Range储存温度(F/C)Trip Delay Range库存样品比较
250A 190 - 480 VacDPDT - 2 Form C扭矩: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (94.4 x 133.9 x 74.9 mm)0 LbUp to 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 10 A @ 240 Vac107%110%Manual; 2 - 300 s adjustableUnder/Over Voltage: 4 s; Unbalance/Phase faults: 2 s查看 Order
250-100-MET 95 - 120 VacDPDT - 2 Form C扭矩: 7 in-lbs; Wire Size: 12 - 18AWG solid or stranded#8 screws2.93 H x 5.27 W x 2.95 D in. (94.4 x 133.9 x 74.9 mm)0公斤Up to 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacManual; 2 - 300 s adjustable-40° to 80°C (-40° to 176°F)Under/Over Voltage: 4 s; Unbalance/Phase faults: 2 s查看 Order
250A-MET 190 - 480 VacDPDT - 2 Form C扭矩: 7 in-lbs; Wire Size: 12 - 18 AWG#8 screws2.93 H x 5.27 W x 2.95 D in. (94.4 x 133.9 x 74.9 mm)0公斤Up to 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac B300; General Purpose: 10 A @ 240 VacManual; 2 - 300 s adjustableUnder/Over Voltage: 4 s; Unbalance/Phase faults: 2 s查看 Order
250600 500 - 600 VacDPDT - 2 Form C扭矩: 7 in-lbs; Wire Size: 12 - 18AWG solid or stranded#8 screws2.93 H x 5.27 W x 2.95 D in. (94.4 x 133.9 x 74.9 mm)0公斤Up to 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac107%110%Manual; 2 - 300 s adjustable-40° to 80°C (-40° to 176°F)Under/Over Voltage: 4 s; Unbalance/Phase faults: 2 s查看 Order
如要索取产品环境信息,请填写 产品环境信息申请表