Littelfuse产品并非为以下用途而设计,也不应被用于这些用途:包括但不限于汽车、航空航天、医疗、救生、维生、核设施、高可靠性应用、用于手术植入体内的装置,或者在产品故障或运行无法达到理想状态的情况下会造成人身伤害、死亡或财产损失的任何其他应用。除非在适用的Littelfuse产品文档中已有明确说明。 如果将产品用于相关Littelfuse文件中未明确说明的任何其他用途,则产品不享受Littelfuse质保。 如果将产品用于相关Littelfuse文件中未明确说明的其他用途,则Littelfuse不会为因此造成的任何索赔或损失承担责任。 除非经Littelfuse另行许可,否则Littelfuse产品的销售和使用应遵守Littelfuse销售条款与条件。 "Littelfuse"包括Littelfuse, Inc.及其所有附属实体。

The 601 series is a fully-programmable voltage monitor designed to protect three-phase motors from loss of any phase (single-phasing), phase reversal, low- or high-voltage, voltage unbalance, low- or high-frequency, and rapid cycling. When a harmful condition is detected, the 601's output relay is deactivated after the specified trip delay. The output relay reactivates after power line conditions return to an acceptable level for the programmed restart delay (RD2). This monitor can be used as a stand-alone product or networked with an RM-1000, RM-2000, PLC, computer, or SCADA system.

Eleven setpoints are viewable with the three-digit LED display or from a networked device:

  • low voltage
  • high voltage
  • voltage unbalance
  • low frequency
  • high frequency
  • RS485 address
  • trip delay for voltage/frequency faults
  • trip delay for single-phase faults
  • rapid-cycle timer (RD1)
  • restart delay after all faults (RD2)
  • type of restart after all faults (manual or automatic)

Six parameters are viewable while the motor is running:
  • L1-L2 voltage
  • L2-L3 voltage
  • L1-L3 voltage
  • average voltage
  • voltage unbalance (%)
  • frequency

When used with the RS485MS-2W communications module, the 601 can communicate with most Modbus RTU master devices. Voltage conditions can be monitored and setpoints can be changed remotely using Solutions software, an RM1000, RM2000, or other device.

功能与特色

  • 内置显示器
  • Programmable voltage and frequency settings
  • Two programmable restart delay timers
  • Two programmable trip delay timers
  • Programmable restart control
  • 灵活复位
  • 远程显示兼容性
  • Network communications capability

请在下方查看规格、认证和存货情况并订购零部件

Catalog #Input
Voltage (V)
Termination TypeMounting MethodDimensionsWeight (lbs/g)AddressHumidityInput AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Over/Under Frequency (%)Overvoltage Reset Voltage (%)Protection ClassRapid Cycle Timer (s)Repeat Accuracy (%)StockSamplesCompare
产品号输入
电压(V)
端接类型安装方法尺寸规格重量(磅/克)地址湿度Input AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Over/Under Frequency (%)Overvoltage Reset Voltage (%)Protection ClassRapid Cycle Timer (s)Repeat Accuracy (%)库存样品比较
601 200 - 480 Vac扭矩: 7 in-lbsSurface mount (4 - #8 screws) or DIN rail mount3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)0公斤A01 - A9910 - 95% non-condensing per IEC 68-2-350 / 605Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac: 35 Hz - HF setting; High: LF setting - 75 Hz97% of HV SettingIP20; NEMA 1 (finger safe)0; 2 - 500 s电压: ±0.5%查看 Order
601575 500 - 600 Vac扭矩: 7 in-lbsSurface mount (4 - #8 screws) or DIN rail mount3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm)0公斤A01 - A9995% non-condensing per IEC 68-2-350 / 605Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac: 35 Hz - HF setting; High: LF setting - 75 Hz97% of HV SettingIP20; NEMA 1 (finger safe)0; 2 - 500 s电压: ±0.5%查看 Order