111-Insider-P 系列 - Littelfuse 111-Insider-P泵监控器提供潜水系统防护

111-insider-p-so-bottom
滚动放大
免责声明

Littelfuse产品并非为以下用途而设计,也不应被用于这些用途:包括但不限于汽车、航空航天、医疗、救生、维生、核设施、高可靠性应用、用于手术植入体内的装置,或者在产品故障或运行无法达到理想状态的情况下会造成人身伤害、死亡或财产损失的任何其他应用。除非在适用的Littelfuse产品文档中已有明确说明。 如果将产品用于相关Littelfuse文件中未明确说明的任何其他用途,则产品不享受Littelfuse质保。 如果将产品用于相关Littelfuse文件中未明确说明的其他用途,则Littelfuse不会为因此造成的任何索赔或损失承担责任。 除非经Littelfuse另行许可,否则Littelfuse产品的销售和使用应遵守Littelfuse销售条款与条件。 "Littelfuse"包括Littelfuse, Inc.及其所有附属实体。

The single-phase 111-Insider-P monitor fits inside ⅓ and ½ hp, 115 V control boxes. It is designed to protect single-phase, submersible pumps from dry-well, dead-head, jammed impellers, rapid-cycle, overvoltage, and undervoltage conditions. A calibration adjustment allows the Insider to be calibrated to your specific pumping applications, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, overcurrent, and undercurrent. When an abnormality such as loss of suction is detected, the product deactivates its output relay and directly disconnects the pump motor. The relay then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the relay reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the relay will operate in manual reset mode.

The Insider communicates with a hand-held diagnostics tool called the Informer (sold separately). The Informer displays parameters including calibration points, trip points, run time and last faults. An IR Kit-12 (12" fiber optic kit) is included with each Insider, allowing the Informer to access these parameters even when the Insider is enclosed in a control box. This is valuable for troubleshooting the pump while it is running.

功能与特色

  • Proprietary microcontroller-based circuitry
  • Onboard sensitivity adjustment
  • Adjustable restart delay
  • Built-in IR communications link
  • LED指示

请在下方查看规格、认证和存货情况并订购零部件

Catalog #Input
Voltage (V)
Input Load Range (hp)Output
Form
Mounting MethodWeight (lbs/g)Overcurrent Trip ClassInput AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Overvoltage Trip Voltage (%)Rapid Cycle Timer (s)Restart Delay RangeTrip Delay RangeUnderload (%)Undervoltage Reset Voltage (%)StockSamples
产品号输入
电压(V)
输入负载范围(hp)输出
型式
安装方法重量(磅/克)Overcurrent Trip ClassInput AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Overvoltage Trip Voltage (%)Rapid Cycle Timer (s)Restart Delay RangeTrip Delay RangeUnderload (%)Undervoltage Reset Voltage (%)库存样品
111-INSIDER-P 115 Vac1/3 - 1/2SPSTInside a Franklin™; Pente®; or CentriPro™ control box0公斤125% of calibration point50 / 60 (50 will increase all delay timers by 20%)51/2 hp @ 120 Vac (17 A max.)132.5 Vac4 restarts allowed in 60 s periodOver/Under Voltage: 2 s; All other faults: Manual; 2 - 225 m过载电流: 5 s; Dry-well: 4 sAdjustable (70 to 90% of calibrated run power)95 Vac查看 Order
如要索取产品环境信息,请填写 产品环境信息申请表