Littelfuse产品并非为以下用途而设计,也不应被用于这些用途:包括但不限于汽车、航空航天、医疗、救生、维生、核设施、高可靠性应用、用于手术植入体内的装置,或者在产品故障或运行无法达到理想状态的情况下会造成人身伤害、死亡或财产损失的任何其他应用。除非在适用的Littelfuse产品文档中已有明确说明。 如果将产品用于相关Littelfuse文件中未明确说明的任何其他用途,则产品不享受Littelfuse质保。 如果将产品用于相关Littelfuse文件中未明确说明的其他用途,则Littelfuse不会为因此造成的任何索赔或损失承担责任。 除非经Littelfuse另行许可,否则Littelfuse产品的销售和使用应遵守Littelfuse销售条款与条件。 "Littelfuse"包括Littelfuse, Inc.及其所有附属实体。

The RM2000 is a motor-monitoring device to be used in conjunction with the 777 family of products (excluding the P1 Series), 77C family of products and the Model 601 voltage monitors, via Modbus protocol with a communications module. The RM-2000/777 motor management system combines unsurpassed electronic motor protection and critical, user-friendly, motor monitoring.
The RM2000 has membrane keypad controls which allow both monitoring and control of a 777 relay through an RS-485 network using Modbus RTU protocol. A second communication port allows monitoring and control of up to 99 RM-2000 devices from a PLC, DCS, or SCADA system or a PC with Solutions software installed. The RM2000 will act as a repeater for its motor protector when accessed from the host computer or PLC. In addition to the monitoring functions, the RM2000 can be used to reset a tripped relay.
The RM2000 is easily mounted remotely and improves safety for service and operations personnel by allowing them to control and monitor the device without opening the electrical cabinet. Using the RM2000 is a simple, cost-effective method for aiding compliance with arc flash safety regulations. The enclosure and keypad assembly is water and ultraviolet light resistant.
参数 (将鼠标移到目标文字上面可显示详情) 数值
Input Voltage (V) 115 Vac
Input Tolerance (%) ±10%
Maximum Input Power 3
Input AC Line Frequency (Hz) 50 / 60
Protection Class NEMA 3R/UL Type 12
Memory Capacity Stores last 4 faults with time and date stamp; includes voltage and current at time of trip
Communications Protocol Modbus RTU
Communications Interface RS-485
Communications Range 50 ft; 4000 ft with separate isolated power supply
Communications Baud Rate (Bps) 300 - 28800
Address A001 - A099
Termination Type 3 in.-lbs.
Mounting Method Surface mountable on backplane using 4 screws
Operating Temperature -20° to 70°C (-4° to 158°F)
Storage Temperature (F/C) -30° to 70°C (-22° to 158°F)
Humidity Up to 85% non-condensing
Dimensions 6.4 H x 6.1 W x 1.1 D in. (162.6 x 154.9 x 27.9 mm)
Weight (lbs/g) 0 Kg
Check Stock Yes
如要索取产品环境信息,请填写 产品环境信息申请表