Flasher and Incandescent Beacon Alarm Relay 系列 - Flasher and Incandescent Beacon Alarm Relay

External overview image
滚动放大
免责声明

Littelfuse产品并非为以下用途而设计,也不应被用于这些用途:包括但不限于汽车、航空航天、医疗、救生、维生、核设施、高可靠性应用、用于手术植入体内的装置,或者在产品故障或运行无法达到理想状态的情况下会造成人身伤害、死亡或财产损失的任何其他应用。除非在适用的Littelfuse产品文档中已有明确说明。 如果将产品用于相关Littelfuse文件中未明确说明的任何其他用途,则产品不享受Littelfuse质保。 如果将产品用于相关Littelfuse文件中未明确说明的其他用途,则Littelfuse不会为因此造成的任何索赔或损失承担责任。 除非经Littelfuse另行许可,否则Littelfuse产品的销售和使用应遵守Littelfuse销售条款与条件。 "Littelfuse"包括Littelfuse, Inc.及其所有附属实体。

The FB120A and FB230A are used to monitor the operation of one two-lamp incandescent beacon and one beacon flasher (or auxiliary module). The flasher and lamps are monitored by sensing the flow of current in the circuit. If the lamp(s) or the flasher fail to operate properly, a solid-state output and an isolated SPDT relay energize. When connected to a site monitoring system, this unit provides the remote beacon monitoring protection required by the FAA/FCC. On a multiple beacon structure, one unit is required for each two-lamp incandescent beacon (one unit per beacon for LED beacons).


工作原理
If one lamp in an incandescent beacon fails, the relay and solidstate lamp failure outputs energize after 10s. If the flasher fails in the ON or OFF condition, the relay and the solid-state flasher failure output energizes after 6s. If both failures occur, all three outputs energize after their trip delays.
: If both incandescent lamps fail, all three outputs will energize. The relay and solid-state flasher failure output energizes after 6s, and the solid-state lamp failure output energizes after 10s.

请在下方查看规格、认证和存货情况并订购零部件

Catalog #Input
Voltage (V)
Output
Form
Trip Delay RangeOutput Load Rating (VA)DimensionsStockSamplesCompare
产品号输入
电压(V)
输出
型式
Trip Delay RangeOutput Load Rating (VA)尺寸规格库存样品比较
FB120A 120 V ac3 total: 1 relay and 2 solid stateFlasher failure: Fixed at 6 s; -0/+40; Lamp failure: Fixed at 10 s; -0/+40%One isolated SPDT relay rated 5 A resistive; Two solid-state line voltage outputs rated 0.5 A steady and 5 A inrush3.5 H x 2.5 W in. (88.9 x 63.5 mm)查看 Order
FB230A 230 V ac3 total: 1 relay and 2 solid stateFlasher failure: Fixed at 6 s; -0/+40; Lamp failure: Fixed at 10 s; -0/+40%One isolated SPDT relay rated 5 A resistive; Two solid-state line voltage outputs rated 0.5 A steady and 5 A inrush3.5 H x 2.5 W in. (88.9 x 63.5 mm)查看 Order