Littelfuse产品并非为以下用途而设计,也不应被用于这些用途:包括但不限于汽车、航空航天、医疗、救生、维生、核设施、高可靠性应用、用于手术植入体内的装置,或者在产品故障或运行无法达到理想状态的情况下会造成人身伤害、死亡或财产损失的任何其他应用。除非在适用的Littelfuse产品文档中已有明确说明。 如果将产品用于相关Littelfuse文件中未明确说明的任何其他用途,则产品不享受Littelfuse质保。 如果将产品用于相关Littelfuse文件中未明确说明的其他用途,则Littelfuse不会为因此造成的任何索赔或损失承担责任。 除非经Littelfuse另行许可,否则Littelfuse产品的销售和使用应遵守Littelfuse销售条款与条件。 "Littelfuse"包括Littelfuse, Inc.及其所有附属实体。

The HRV combines the accuracy of microcontroller based circuitry with an electromechanical relay output. The HRV's switching capacity allows direct control of loads like compressors, pumps, motors, heaters, and lighting. The HRV "S" version provides a vend time after the selected number of initiate switch closures to start is reached. The HRV "A" version includes all of the "S" features and allows the total vend time to be extended for each additional initiate switch closure. The HRV is ideal for cost sensitive single coin or token vending machines. The electronic circuitry is encapsulated to protect against humidity and vibration.


工作原理
Coin Totalizer & Vending Timer (“S” Version):
Input voltage must be applied prior to & during operation. When the total number of S1 initiate switch closures equals the number to start set on the lower 3 DIP switches, the load energizes and the vending time set on the upper 7 DIP switches begins. At the end of the vending time, the load de-energizes and the vending time is reset. Closing the initiate switch during vend timing will have no affect on vend time delay.
Accumulating Vending Timer (“A” Version):
Input voltage must be applied prior to & during operation. When the total number of S1 initiate switch closures equals the number to start set on the lower 3 DIP switches, the load energizes and the vending time starts. For every initiate switch closure, the HRV unit adds one time per coin period, as set on the upper 7 DIP switches, to the total vending time.
操作注意事项: If S1 is closed when input voltage is applied, the output remains de-energized and the S1 counter remains at zero closures. At least one "vend time" and one "closures to start" DIP switch must be in the "ON" position for proper operation.
重置: Removing input voltage resets the vend time delay, the S1 closure counter, and de-energizes the output relay.

请在下方查看规格、认证和存货情况并订购零部件

Catalog #Input
Voltage (V)
Output
Form
Count RangeStorage Temperature (F/C)Time Delay RangeDimensionsStockSamplesCompare
产品号输入
电压(V)
输出
型式
Count Range储存温度(F/C)延时范围尺寸规格库存样品比较
HRV11SC 12 V dcIsolated SPDT - NO1 - 7 counts to start-40° to 85°C (-40° to 185°F)Adjustable 1 - 127 s3 H x 2 W in. (76.7 x 51.3 mm)查看 Order
HRV24AC 24 V acIsolated SPDT - NO1 - 7 counts to start; maximum: 250-40° to 85°C (-40° to 185°F)Adjustable 0.25 - 31.75 m3 H x 2 W in. (76.7 x 51.3 mm)查看 Order
HRV41AE 120 V acIsolated SPDT - NO1 - 7 counts to start; maximum: 250-40° to 85°C (-40° to 185°F)Adjustable 1 - 127 s3 H x 2 W in. (76.7 x 51.3 mm)查看 Order
HRV41SE 120 V acIsolated SPDT - NO1 - 7 counts to start-40° to 85°C (-40° to 185°F)Adjustable 1 - 127 s3 H x 2 W in. (76.7 x 51.3 mm)查看 Order
HRV42SE 120 V acIsolated SPDT - NO1 - 7 counts to start-40° to 85°C (-40° to 185°F)Adjustable 5 - 635 s3 H x 2 W in. (76.7 x 51.3 mm)查看 Order
HRV43AE 120 V acIsolated SPDT - NO1 - 7 counts to start; maximum: 250-40° to 85°C (-40° to 185°F)Adjustable 0.1 - 12.7 m3 H x 2 W in. (76.7 x 51.3 mm)查看 Order
HRV43AN 120 V acNon-isolated SPDT - NO1 - 7 counts to start; maximum: 250-40° to 85°C (-40° to 185°F)Adjustable 0.1 - 12.7 m3 H x 2 W in. (76.7 x 51.3 mm)查看 Order
HRV43SE 120VACIsolated SPDT NO1-7 counts to start-40° to 85°C (-40°F to 185°F)Adjustable 0.1 - 12.7m3.00 x 2.00 x 1.50 in. (76.7 x 51.3 x 38.1mm)